Data Aire DAFC-11 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Climatiseurs à système divisé Data Aire DAFC-11. FLUID COOLERS Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - FLUID COOLERS

FLUID COOLERSSELECTION GUIDEandOPERATION and MAINTENANCE MANUAL

Page 2

10Fan Motor Controls Fluid cooler fan motors are cycled on and off by individual water-sensing thermostats strapped to the leaving water header. The

Page 3 - TABLE OF CONTENTS

11Glycol System Concentration Fill the system with water and suffi cient antifreeze (ethylene or propylene glycol) to protect the system against winte

Page 4 - Guide Specifi cations

12Electrical Service Check to be sure the service provided by the utility is suffi cient to handle the additional load imposed by the fl uid coolers.

Page 5 - 95 100 105

13Preventive MaintenanceThe operating life of the DAFC fl uid cooler can be extended by following a simple preven-tive maintenance schedule. This sche

Page 6

14Fluid CoolersDAFC Model 06-50

Page 7 - Based on 40% Glycol

15Fluid CoolersDAFC Model 06-50

Page 8

16Double Wide Fluid CoolersDAFC Model 57 thru 100

Page 10

18Expansion Tank - 10 Gallon

Page 11

19Fluid Cooler Internal Volume Fluid Cooler Internal Volume Fluid Cooler Internal Volume Model Volume, Gallons Model Volume, Gallons DAFC 0

Page 13 - Preventive Maintenance

20DAFC-PB Fluid CoolerGuide Specifi cationsCABINET AND FRAME - The frame shall be constructed of 14 gauge welded tubular steel and be coated with a hea

Page 14 - DAFC Model 06-50

21Indoor Fluid Cooler Selection Chart95° Ambient Model THR GPM Fluid Cooler MBH PDData Temp DT*D/U-02 36 7.0 DAFC-06-PB 49 1.1 DT*D/U-03 4

Page 15

22Data Aire Piggy Back Heat ExchangeDAFC 6, 7 and 9 ton

Page 16 - DAFC Model 57 thru 100

23Data Aire Piggy Back Heat ExchangeDAFC 11, 15 and 17 ton

Page 17 - Pump Cover Enclosures

24Data Aire Piggy Back Heat ExchangeDAFC 21, 24 and 28 ton

Page 18 - Expansion Tank - 10 Gallon

25Notes_______________________________________________________________________________________________________________________________________________

Page 19 - Fluid Cooler Internal Volume

Notes_________________________________________________________________________________________________________________________________________________

Page 21

230 W. BlueRidge AvenueOrange, CA 92865800-347-2473www.dataaire.com e-mail: [email protected] Member of the CS Group of Companies© 2010 Data A

Page 22 - DAFC 6, 7 and 9 ton

3TABLE OF CONTENTSExternal Fluid CoolersDAFC - Guide specifi cations ... 4DAFC - Selecti

Page 23 - DAFC 11, 15 and 17 ton

4Data Aire Fluid Cooler - DAFCGuide Specifi cationsUnit Cabinet - Casings shall be constructed of heavy gauge aluminum, thoroughly rein-forced with riv

Page 24 - DAFC 21, 24 and 28 ton

5Standard Fluid Cooler Selection ChartAll selections based on 40% Glycol Ambient Temperature 95 100 1051 Fluid PD Fluid PD Fluid PDModel

Page 25

6Low Decibel Fluid Cooler Selection ChartAll selections based on 40% glycol Ambient Temperature 95 100 1051 Fluid PD Fluid PD Fluid PDMod

Page 26

7DAFC Fluid Cooler Capacity BreakdownBased on 40% Glycol DAFC 06 DAFC 07 DAFC 09 DAFC 11 DAFC 15 DAFC 17 DAFC 21 GPM MBH/PD MBH/PD MBH/PD

Page 27

8DAFC Fluid Cooler Capacity Breakdown - ContinuedBased on 40% Glycol DAFC 57 DAFC 61 DAFC 75 DAFC 80 DAFC 88 DAFC 100 GPM MBH/PD MBH/PD MBH/

Page 28 - FC-SG-IOM 01/06B

9Installation and MaintenanceInspection This Data Aire unit has been factory run-tested and passed a comprehensive inspection prior to its packaging

Commentaires sur ces manuels

Pas de commentaire